Pilot-IH - Field Wiring

Proper installation and connection of the two-way module two-wire paths is very important. To learn how to make a proper wire connection please watch the video below.

  • Use only Hunter IDWIRE or an approved substitute.
  • Use only Hunter DBRY-6 waterproof connectors in the red and blue two-wire path connections.
  • Leave adequate slack (about 5' or 1.5 m) at each splice to prevent disconnection.

Each PILOTDH250 output module supports up to 250 two-way module stations.

  • Each module allows up to six two-wire path connections.
  • Each path may be up to 10,000' (3 km) with 14 AWG (2 mm2) wire or up to 15,000' (4.5 km) with 12 AWG (approximately 3.31 mm2) wire.
  • Two-wire paths may be tee-spliced (in a valve box with approved connectors) as long as the maximum distance to each end of the paths from the controller does not exceed the maximum for the wire used.
ModelInput WireStation Output #1Station Output #2Station Output #3Station Output #4Station Output #5Station Output #6
Pilot - 100Red/BlueBlack/BlackN/AN/AN/AN/AN/A
Pilot - 200Red/BlueBlack/BlackYellow/YellowN/AN/AN/AN/A
Pilot - 400Red/BlueBlack/BlackYellow/YellowGreen/GreenWhite/WhiteN/AN/A
Pilot - 600Red/BlueBlack/BlackYellow/YellowGreen/GreenWhite/WhiteOrange/OrangePurple/Purple

 

 