Hunter Two-Wire/Decoder Comparison
 ICD
Product Name

ICD

EZ Decoder System (EZDS)

Compatible Controllers

ACC2
Legacy ACC

HCC & ICC2
(EZDM)

HPC & Pro-C
(PCDM)

Max. Decoder Stations per System

225

54

28

Wire Options

ID1 - 14 AWG

ID2 - 12 AWG

Any low-voltage, direct-burial wire will suffice

Maximum Wiring Distance

10,000'

15,000'

EZ-1: 3,808' (12 AWG) | EZ-LR: 7,616' (12 AWG)

Wire Connectors

DBRY-6

Waterproof connections are encouraged

Two-wire Paths Available

3 per 75 station module (9 max.)

EZDM - 2
PCDM - 1

Decoder Station Options

1-, 2-, 4-, 6-station (& ICD-SEN sensor decoder)

Single-station

Earth Grounding Required for Two-Wire Path

Yes

No

Hybrid Conventional/Decoder Operation

No

Yes

Programmable Sensor Decoders

Yes

No

Programmable P/MV Decoders

Yes

Yes

Handheld Programmer/Wireless Diagnostic Tool

ICD-HP

EZ-DT

Warranty

5 years

3 years