Landscape Irrigation
Landscape Irrigation
The chart below indicates the maximum wire runs that can be used when installing Hunter AC solenoid valves with controllers. The example in the chart below demonstrates the most commonly used wire size for station control and ground wire ( e.g.,12 AWG = …
Below is a chart indicating the maximum wire runs that can be used when installing Hunter AC solenoids and valves. Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and Valve) Ground Wire Size Control Wire (ft) 18 AWG / 1.0 mm 16 …
The chart below indicates the maximum wire runs that can be used when installing Hunter AC solenoid valves with controllers. The example in the chart below demonstrates the most commonly used wire size for station control and ground wire ( e.g.,12 AWG = …
The HPC face panel quickly and easily upgrades Pro-C® controllers (PC400 models manufactured since March 2014) to next-generation smart controllers via the Hydrawise platform. It also allows end users and contractors to manually operate their systems …
With the Pro-C controller in production for 17 years, we have continuously upgraded it to accommodate innovative features. Below, you will find every panel we manufactured for the Pro-C model, including the NEW Wi-Fi replacement front panel. For …
Owner’s manual, installation, and programming instructions for Wireless Valve Controller and Programmer is available in a downloadable PDF format. … WVP/WVC - Owner's …
Selecting Specific Days of the Week to Water For specific day of the week watering, the station number and 7 days of the week with a icon or a icon above the numbered day will be displayed. The icon would represent an "ON" watering day, while …
ACC2 can be updated whenever a new version of the operating system or any of the internal modules are released. These updates are available at the bottom of this article in the resources section. It is always advisable to stay current with controller …
The MP Rotator Standard Nozzle Family has a matched precipitation rate of approximately 0.4 in/hr (10 mm/hr). This means any MP Rotator Standard model at any arc or radius can be placed in the same zone. The MP800 Family has a precipitation rate of …
Here is a list of the error codes and ways to troubleshoot them: X2 - Controller code CODE description SOLUTION FAIL Wi-Fi setup failed Check the spelling of the network name (SSID) and/or password and reconnect to Wi-Fi donE The previous operation is …
The CLIK DELAY option is designed to set number of days for watering to remain off, after sensor has been activated and restored. … X2 - …
Simply twist the solenoid on the valve counter clockwise 1/4 turn to 1/2 a turn. To shut off the valve, twist the solenoid clockwise until it is snug on the valve. … How do I manually open a zone control valve without using the …
The program(s) should already be configured after you finish the setup wizard, but you may want to adjust your run times, start times, or water days later. The X2 Standard Mode programming allows you to create traditional irrigation programs using …
It is important to understand that Solar Sync provides a global seasonal adjustment to the controller. This means that all station run times will be modified by the seasonal adjustment percentage shown. When programming the controller, the run times …
After connecting one or more flow sensors to the controller, the next step is to configure the sensor in the FLOW SENSORS menu. The controller has three Flow Sensor inputs built-in, but three more can be added with the A2C-F3 Flow Expansion Module. ACC2 …
From a battery life standpoint, the answer is not as easy as saying "the batteries will last for two years". The answer really depends upon the number of actuations that the controller operates over a given period of time. The chart below provides the …
A common reason for a controller to repeat a cycle is too many programmed start times. Only one start time per active program is required, a second start time will cycle the program an additional time. NOTE: In the Start Times dial position, the numbers …
W e would prefer that you use a Hunter valve with a Hunter DC latching solenoid, but we realize that sometimes you may be retrofitting existing systems with another manufacturer’s valves. We have tested the following solenoids and found that they operate …
The XC Hybrid operates on six AA alkaline batteries, and the XC Hybrid Stainless uses six C batteries. A battery carrier is supplied with your controller. Insert the batteries as indicated on the battery carrier. Connect that battery connector inside the …
The chart below indicates maximum wire lengths when using a Hunter DC latching solenoid combined with a Hunter XC Hybrid controller. WIRE SIZE MAXIMUM DISTANCE* FEET METERS 18 AWG / 1.0 mm 550 168 16 AWG / 1.2 mm 870 265 14 AWG / 1.6 mm 1380 420 12 AWG …
When designing and installing irrigation systems, the water stream's trajectory and spray height leaving a sprinkler nozzle is important information. The chart below will show the total feet of height when using the largest nozzle for the ST-1600 model. …
When using the residential central Wi-Fi adapter with the I2C commercial controller, there are some common LED usage lights that will help you determine the communication. LED Description 1st Flash Red when in direct connect mode. Flash Green when …
If your controller shows irrigation running (Flashing Sprinkler Icon), and your sprinklers are not working, you may have a wiring problem at the valves or the irrigation water supply has been shut down. If you have a master valve on your system (check for …
Here is a list of the error codes and ways to troubleshoot them: … CAUSE - The Station # ERR (for example 1 ERR) is a diagnostic message that appears when your controller is detecting a fault on that corresponding irrigation zone. SOLUTION - To …