Operating Specifications

  • Radius: 50' to 67'
  • Flow rate: 6.5 to 20.8 GPM
  • Recommended pressure range: 40 to 60 PSI
  • Operating pressure range: 20 to 100 PSI
  • Precipitation rates: 0.4 in/hr approx.
  • Nozzle trajectory: 25 degrees

Özellikler

For all the municipal, sports, and commercial sites where low pressure persists, the I-60 is here. The I-60 was designed to provide low-pressure systems with long-range ability. This great innovation stops sites such as municipalities, city parks or community sports complexes from needing expensive pumps and large pipes required to boost pressure.

Tablolar

 
I-60-ADS Nozzle Performance Data
Nozzle Pressure Radius Flow Precip in/hr
  PSI ft GPM
Orange
40 50 6.5 0.50 0.58
50 52 7.1 0.51 0.58
60 54 7.7 0.51 0.59
10 
Lt. Green
40 53 8.5 0.58 0.67
50 56 9.5 0.58 0.67
60 58 10.2 0.58 0.67
13 
Lt. Blue*
40 56 10.5 0.64 0.74
50 58 12.1 0.69 0.80
60 60 13.0 0.70 0.80
15 
Gray
40 58 12.5 0.72 0.83
50 60 13.9 0.74 0.86
60 62 15.1 0.76 0.87
18 
Red
40 59 15.6 0.86 1.00
50 62 17.5 0.88 1.01
60 65 18.6 0.85 0.98
20 
Dk. Brown
40 62 17.5 0.88 1.01
50 64 19.1 0.90 1.04
60 66 20.4 0.90 1.04

* Factory-installed nozzle

Notes:
All precipitation rates calculated for 180 degree operation. For the precipitation rate for a 360 degree sprinkler, divide by 2.

 
I-60-36S Nozzle Performance Data
Nozzle Pressure Radius Flow Precip in/hr
  PSI ft GPM
Orange

40

51

6.5

0.24

0.28

50 54 7.5 0.25 0.29

60

56

8.0

0.25

0.28

10 
Lt. Green
40 53 8.5 0.29 0.34
50 56 9.5 0.29 0.34
60 58 10.2 0.29 0.34
13 
Lt. Blue*

40

56

10.5

0.32

0.37

50 58 12.4 0.35 0.41

60

60

13.0

0.35

0.40

15 
Gray
40 58 12.5 0.36 0.41
50 60 14.0 0.37 0.43
60 62 15.1 0.38 0.44
18 
Red
40 59 15.6 0.43 0.50
50 62 17.7 0.44 0.51
60 65 18.9 0.43 0.50
20 
Dk. Brown
40 62 17.5 0.44 0.51
50 64 19.1 0.45 0.52
60 67 20.8 0.45 0.51

* Factory-installed nozzle