Proper installation and connection of the two-way module two-wire paths is very important. To learn how to make a proper wire connection please watch the video below.
- Use only Hunter IDWIRE or an approved substitute.
- Use only Hunter DBRY-6 waterproof connectors in the red and blue two-wire path connections.
- Leave adequate slack (about 5' or 1.5 m) at each splice to prevent disconnection.
Each PILOTDH250 output module supports up to 250 two-way module stations.
- Each module allows up to six two-wire path connections.
- Each path may be up to 10,000' (3 km) with 14 AWG (2 mm2) wire or up to 15,000' (4.5 km) with 12 AWG (approximately 3.31 mm2) wire.
- Two-wire paths may be tee-spliced (in a valve box with approved connectors) as long as the maximum distance to each end of the paths from the controller does not exceed the maximum for the wire used.
Model | Input Wire | Station Output #1 | Station Output #2 | Station Output #3 | Station Output #4 | Station Output #5 | Station Output #6 |
Pilot - 100 | Red/Blue | Black/Black | N/A | N/A | N/A | N/A | N/A |
Pilot - 200 | Red/Blue | Black/Black | Yellow/Yellow | N/A | N/A | N/A | N/A |
Pilot - 400 | Red/Blue | Black/Black | Yellow/Yellow | Green/Green | White/White | N/A | N/A |
Pilot - 600 | Red/Blue | Black/Black | Yellow/Yellow | Green/Green | White/White | Orange/Orange | Purple/Purple |