Landscape Irrigation
Landscape Irrigation
Arc | Pressure | Radius | Flow | Precip in/hr | |||
PSI | ft | GPM | |||||
90° | 30 | 20 | 0.85 | 0.82 | 0.94 | ||
35 | 21 | 0.93 | 0.81 | 0.94 | |||
40 | 22 | 0.97 | 0.77 | 0.89 | |||
45 | 23 | 1.06 | 0.77 | 0.89 | |||
50 | 24 | 1.11 | 0.74 | 0.85 | |||
55 | 24 | 1.16 | 0.77 | 0.89 | |||
180° | 30 | 20 | 1.72 | 0.83 | 0.96 | ||
35 | 21 | 1.82 | 0.79 | 0.91 | |||
40 | 22 | 2.01 | 0.80 | 0.92 | |||
45 | 22 | 2.06 | 0.82 | 0.95 | |||
50 | 23 | 2.21 | 0.80 | 0.93 | |||
55 | 24 | 2.36 | 0.79 | 0.91 | |||
210° | 30 | 20 | 1.94 | 0.80 | 0.92 | ||
35 | 21 | 2.10 | 0.78 | 0.91 | |||
40 | 22 | 2.36 | 0.81 | 0.93 | |||
45 | 22 | 2.39 | 0.81 | 0.94 | |||
50 | 23 | 2.52 | 0.79 | 0.91 | |||
55 | 24 | 2.66 | 0.76 | 0.88 | |||
270° | 30 | 20 | 2.53 | 0.81 | 0.94 | ||
35 | 21 | 2.74 | 0.80 | 0.92 | |||
40 | 22 | 3.00 | 0.80 | 0.92 | |||
45 | 22 | 3.12 | 0.83 | 0.96 | |||
50 | 23 | 3.30 | 0.80 | 0.93 | |||
55 | 24 | 3.48 | 0.78 | 0.90 | |||
360° | 30 | 20 | 3.40 | 0.82 | 0.94 | ||
35 | 21 | 3.68 | 0.80 | 0.93 | |||
40 | 22 | 3.97 | 0.79 | 0.91 | |||
45 | 22 | 4.08 | 0.81 | 0.94 | |||
50 | 23 | 4.30 | 0.78 | 0.90 | |||
55 | 24 | 4.53 | 0.76 | 0.87 |
Bold = Optimal pressure for the MP Rotator is 40 PSI. This can easily be achieved by using the MP Rotator with the Pro-Spray PRS40 Sprinkler Body, pressure regulated at 40 PSI.
1" PGV and PGV Jar-Top Pressure Loss in PSI | ||||
---|---|---|---|---|
Flow GPM | 1" Globe | 1" Angle | 1" Male x Male | 1" Male x Barb |
1 | 3 | 1 | 2 | 2 |
5 | 4 | 1 | 2 | 2 |
10 | 4 | 1 | 2 | 2 |
15 | 5 | 1 | 3 | 3 |
20 | 5 | 2 | 4 | 4 |
25 | 6 | 2 | 7 | 6 |
30 | 8 | 3 | 10 | 10 |
40 | 14 | 5 | 18 | 16 |
The Wireless Valve Link product family eliminates some of the biggest contractor costs in irrigation installations: copper wire and unnecessary excavation to connect or repair distant valves. Like decoders, it replaces commodity wire with Hunter ingenuity and provides an efficient alternative to activating irrigation valves. Once connected, wireless signals are immune to issues that commonly afflict wired systems, such as wire degradation and lightning damage.
Arc | Pressure | Radius | Flow | Precip in/hr | |||
PSI | ft | GPM | |||||
90° | 30 | 14 | 0.42 | 0.83 | 0.95 | ||
35 | 15 | 0.46 | 0.79 | 0.91 | |||
40 | 15 | 0.49 | 0.84 | 0.97 | |||
45 | 16 | 0.52 | 0.78 | 0.90 | |||
50 | 16 | 0.55 | 0.83 | 0.96 | |||
55 | 16 | 0.58 | 0.87 | 1.01 | |||
180° | 30 | 13 | 0.75 | 0.85 | 0.99 | ||
35 | 14 | 0.86 | 0.84 | 0.98 | |||
40 | 15 | 0.93 | 0.80 | 0.92 | |||
45 | 15 | 0.96 | 0.82 | 0.95 | |||
50 | 16 | 1.06 | 0.80 | 0.92 | |||
55 | 16 | 1.11 | 0.83 | 0.96 | |||
210° | 30 | 13 | 0.88 | 0.86 | 0.99 | ||
35 | 14 | 0.96 | 0.81 | 0.93 | |||
40 | 15 | 1.10 | 0.81 | 0.93 | |||
45 | 15 | 1.16 | 0.85 | 0.98 | |||
50 | 16 | 1.24 | 0.80 | 0.92 | |||
55 | 16 | 1.30 | 0.84 | 0.97 | |||
270° | 30 | 13 | 1.14 | 0.87 | 1.00 | ||
35 | 14 | 1.24 | 0.81 | 0.94 | |||
40 | 15 | 1.40 | 0.80 | 0.92 | |||
45 | 15 | 1.47 | 0.84 | 0.97 | |||
50 | 16 | 1.54 | 0.77 | 0.89 | |||
55 | 16 | 1.61 | 0.81 | 0.93 | |||
360° | 30 | 13 | 1.52 | 0.87 | 1.00 | ||
35 | 14 | 1.70 | 0.83 | 0.96 | |||
40 | 15 | 1.87 | 0.80 | 0.92 | |||
45 | 15 | 2.00 | 0.86 | 0.99 | |||
50 | 16 | 2.13 | 0.80 | 0.92 | |||
55 | 16 | 2.26 | 0.85 | 0.98 |
Bold = Optimal pressure for the MP Rotator is 40 PSI. This can easily be achieved by using the MP Rotator with the Pro-Spray PRS40 Sprinkler Body, pressure regulated at 40 PSI.
Cost and complexity have often limited decoder technology to higher-end systems. However, with the revolutionary EZ Decoder System (EZDS), you get all the advantages of two-wire installations with simpler, more cost-effective technology — so you can bring the power of two-wire control to more projects than ever before.