- I-CORE CONTROLLER
- DUAL -1 (One-Station Decoder) Not Compatible with Master valve/Pump Start Relay or Weather Sensor
- MAX DISTANCE TO END OF TWO-WIRE PATH
ID1 WIRE (14 Ga) 5000 feet (1500m)
ID2 WIRE (12 Ga) 7500 feet (2300m) - DUAL-S SURGE ARRESTOR (Recommended every 1000 feet, 330 m)
- GROUND PLATE (Or ground rod)
- DBR/Y-6 WATERPROOF CONNECTORS in all two-wire path splices
- DUAL-2 (two-station decoder)
- MAXIMUM DISTANCE 5000 FEET (1500 m) to end of two-wire path
- DUAL-S (Placed at the end of the two-wire path)
Note: Dual decoders are for Station Valves only. Pump/Master Valve and Sensors must be wired separately to the corresponding terminals in the controller.
Decoder | DUAL I-Core System | ACC/ACC2 Systems |
---|---|---|
DUAL-1 | Compatible | Not Compatible |
DUAL-2 | Compatible | Not Compatible |
ICD-100 | Compatible | Compatible |
ICD-200 | Compatible | Compatible |
ICD-400 | Compatible | Compatible |
ICD-600 | Compatible (Requires the ICD-HP to Program station assignments) Dual will report a "Not supported" error if programming is attempted at the DUAL module. | Compatible |
ICD-SEN | Not Compatible (Sensors are to be hardwired only on Dual systems) | Compatible |