Specifications
HC Flow Model | HC-075-FLOW (¾") | HC-100-FLOW (1") | HC-150-FLOW (1½") | HC-200-FLOW (2") |
---|---|---|---|---|
Inlet/outlet connection size | ¾" NPT body, male thread | 1" NPT body, male thread | 1½" NPT body, male thread | 2" NPT body, male thread |
Meter internal diameter | 3/4" | 1" | 1.5" | 2" |
Minimum flow (GPM) | 0.22 | 0.3 | 0.88 | 1.98 |
Maximum recommended flow (GPM) | 15 | 30 | 66 | 105 |
Maximum flow rate (GPM) | 21 | 34 | 88 | 132 |
Dial reading (US gal) | 1 pulse per 0.1 U.S. gal | 1 pulse per 1 U.S. gal | 1 pulse per 1 U.S. gal | 1 pulse per 1 U.S. gal |
Maximum working pressure (PSI) | 230 | 230 | 230 | 230 |
Included Wire Length | 29" total wire length with first 8" having flex conduit. | |||
Flex Conduit Thread Spec | Threading measures ¼” BSP, which would also fit ¼” NPT for all models. The exact thread size of the stainless steel fitting is 1/4-28. |
Pressure Loss Chart
Still need help? We're here.