Wireless Mini-Clik Sensor - Components

Wireless Mini-Clik Sensor
  1. Manual Test Spindle: Press and hold the manual test spindle to confirm the proper operation of your sensor.
  2. Vent Cap and Spindle: Used to adjust reset rate or dry out time for the sensor.
  3. Radio Antenna: Transmits a wireless signal to the receiver up to 800' (243 m) line of sight. The antenna should be oriented vertically.
  4. Mounting Arm: Metal extension arm for mounting the sensor.
  5. Battery Status LED: Used to determine the status of the sealed battery. Pushing the manual test spindle will flash the LED light indicating that the battery is good.

 
Wireless Receiver
  1. Bypass Button: Allows automatic or manual watering when the sensor is active.
  2. Receiver Status LED: Used to indicate the status of the sensor.
  3. Receiver Bypass LED: Indicates when sensor has been bypassed.
  4. Radio Antenna: Receives a wireless signal from the transmitter up to 800' (243 m) line of sight. The antenna should be oriented vertically.
  5. AC Power Wires: The two yellow wires are attached to a 24 VAC source from the controller.
  6. Receiver Wires: The sensor wires are attached to either the sensor terminals in the controller or in-line with the valve common wire.
    • Blue/White Wires: Used for normally closed sensor applications (Hunter controllers).
    • Orange/White Wires: Used for normally open sensor applications.
  7. Rubber Cover: Used to protect the receiver when mounted in outdoor locations.

Still need help? We're here.

Tell us what you need support with and we'll find the best solution for you.

Contact Support