PGV-151-B | PGV Valve, screw-top, 1½" (40 mm) BSP combination globe/angle valve with flow control and female thread inlet / outlet | + |
PGV-151-B-DC | PGV Valve, screw-top, 1½" (40 mm) BSP combination globe / angle valve with flow control, female thread inlet / outlet, and DC-Latching Solenoid | + |
PGV-151-B-LS | PGV Valve, screw-top, 1½" (40 mm) BSP combination globe / angle valve with flow control and female thread inlet / outlet; no solenoid | + |
PGV-201-B | PGV Valve, screw-top, 2" (50 mm) BSP combination globe / angle valve with flow control and female thread inlet / outlet | + |
PGV-201-B-DC | PGV Valve, screw-top, 2" (50 mm) BSP combination globe / angle valve with flow control, female thread inlet / outlet, and DC-Latching Solenoid | + |
PGV-201-B-LS | PGV Valve, screw-top, 2" (50 mm) BSP combination globe / angle valve with flow control and female thread inlet / outlet; no solenoid | + |
Create a new My List.
Contact your local distributor for product availability and ordering.
Specifications
User-Installed Options
- Accu Sync™ pressure regulation at the valve*
- DC-latching solenoid for battery-powered controllers (P/N 458200)
- Solenoid conduit cover (P/N 464322)
- Reclaimed flow control handle (P/N 607105)
Factory-Installed Options
- LS: Valve without solenoid
- DC: DC-latching solenoid for battery-powered controllers
1" (25 mm) PGV Operating Specifications
- Flow: 0.05 to 9 m3 /hr; 0.7 to 150 l/min
- Recommended pressure range: 1.5 to 10 bar; 150 to 1,000 kPa
- Temperature rating: 66°C
- Warranty period: 2 years
- View more details for 1" PGV >
1½" (40 mm) And 2" (50 mm) PGV Operating Specifications
- Flow:
- PGV-151: 5 to 27 m3 /hr; 75 to 450 l/min
- PGV-201: 5 to 34 m3 /hr; 75 to 570 l/min
- Recommended pressure range: 1.5 to 10 bar; 150 to 1000 kPa
- Temperature rating: 66°C
- Warranty period: 2 years
1" (25 mm) PGV Pressure Loss
1" (25 mm) PGV Pressure Loss in Bar | |
---|---|
Flow m3/hr | Pressure Loss bar |
0.3 | 0.08 |
1.0 | 0.11 |
2.5 | 0.13 |
3.5 | 0.16 |
4.5 | 0.23 |
5.5 | 0.43 |
6.5 | 0.62 |
8.0 | 1.10 |
9.0 | 1.48 |
1" (25 mm) PGV Pressure Loss in KPa | |
---|---|
Flow l/min | Pressure Loss kPa |
4 | 8 |
20 | 11 |
40 | 13 |
55 | 16 |
75 | 23 |
95 | 43 |
115 | 62 |
135 | 110 |
150 | 148 |
1½" (40 mm) and 2" (50 mm) PGV Pressure Loss
PGV Pressure Loss in Bar | ||||
---|---|---|---|---|
Flow m3/hr | 1½" (40 mm) Globe | 1½" (40 mm) Angle | 2" (50 mm) Globe | 2" (50 mm) Angle |
4.5 | 0.2 | 0.2 | 0.1 | 0.1 |
5.5 | 0.2 | 0.2 | 0.1 | 0.1 |
6.5 | 0.2 | 0.2 | 0.1 | 0.1 |
8.0 | 0.2 | 0.2 | 0.1 | 0.1 |
9.0 | 0.2 | 0.2 | 0.1 | 0.1 |
11.0 | 0.3 | 0.2 | 0.1 | 0.1 |
13.5 | 0.3 | 0.3 | 0.1 | 0.1 |
18.0 | 0.4 | 0.4 | 0.2 | 0.1 |
22.5 | 0.6 | 0.5 | 0.3 | 0.2 |
27.0 | 0.8 | 0.8 | 0.4 | 0.3 |
30.5 | 0.6 | 0.5 | ||
34.0 | 0.7 | 0.6 |
PGV Pressure Loss in kPa | ||||||
---|---|---|---|---|---|---|
Flow l/min | 1½" (40 mm) Globe | 1½" (40 mm) Angle | 2" (50 mm) Globe | 2" (50 mm) Angle | ||
75 | 20 | 22 | 4 | 9 | ||
95 | 20 | 21 | 5.5 | 9 | ||
115 | 21 | 21 | 7.5 | 9.5 | ||
135 | 22 | 21 | 9 | 10 | ||
150 | 25 | 23 | 12 | 11 | ||
200 | 27 | 24 | 14 | 12 | ||
325 | 47 | 41 | 26 | 19 | ||
400 | 65 | 59 | 33 | 24 | ||
500 | 96 | 92 | 43 | 32 | ||
625 | 56 | 45 | ||||
775 | 74 | 64 |
Solenoid Specifications
- 24 VAC solenoid
- 350 mA inrush, 190 mA holding, 60 Hz
- 370 mA inrush, 210 mA holding, 50 Hz
Videos
Pagination
Features
This hard working, heavy-duty valve offers the best features of Hunter’s top-of-the-line valves. Built with enough durability to handle the rigors of most residential and light commercial sites, the PGV is available in an array of configurations. For smaller landscape applications, the PGV is available in four 25 mm body configurations: angle, globe, or male x male design. In turn, each model is available in either a flow control or non-flow control version. For larger landscape applications, the PGV comes in both 40 mm and 50 mm globe/angle models (with flow control). All models feature durable high-grade construction and a rugged diaphragm with support to prevent stress failure.
Key Benefits
Advanced Features
Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone. Learn more about flow control.
Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.
Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.
Valve Models
PGV-101, PGV-100JT, PGV101JT
- Reclaimed Water Handle P/N: 269205
PGV-151, PGV-201
- Reclaimed Water Handle P/N: 607105
ICV101, ICV151, ICV201
- Reclaimed Water Handle P/N: 561205
ICV301
- Reclaimed Water Handle P/N: 515005
Charts
1" (25 mm) PGV Valve | |
---|---|
Flow m3/hr | Pressure Loss bar |
0.3 | 0.08 |
1.0 | 0.11 |
2.5 | 0.13 |
3.5 | 0.16 |
4.5 | 0.23 |
5.5 | 0.43 |
6.5 | 0.62 |
8.0 | 1.10 |
9.0 | 1.48 |
1" (25 mm) PGV Valve | |
---|---|
Flow l/min | Pressure Loss kPa |
4 | 8 |
20 | 11 |
40 | 13 |
55 | 16 |
75 | 23 |
95 | 43 |
115 | 62 |
135 | 110 |
150 | 148 |
PGV Pressure Loss in Bar | ||||
---|---|---|---|---|
Flow m3/hr | 1½" (40 mm) Globe | 1½" (40 mm) Angle | 2" (50 mm) Globe | 2" (50 mm) Angle |
4.5 | 0.2 | 0.2 | 0.1 | 0.1 |
5.5 | 0.2 | 0.2 | 0.1 | 0.1 |
6.5 | 0.2 | 0.2 | 0.1 | 0.1 |
8.0 | 0.2 | 0.2 | 0.1 | 0.1 |
9.0 | 0.2 | 0.2 | 0.1 | 0.1 |
11.0 | 0.3 | 0.2 | 0.1 | 0.1 |
13.5 | 0.3 | 0.3 | 0.1 | 0.1 |
18.0 | 0.4 | 0.4 | 0.2 | 0.1 |
22.5 | 0.6 | 0.5 | 0.3 | 0.2 |
27.0 | 0.8 | 0.8 | 0.4 | 0.3 |
30.5 | 0.6 | 0.5 | ||
34.0 | 0.7 | 0.6 |
PGV Pressure Loss in kPa | ||||||
---|---|---|---|---|---|---|
Flow l/min | 1½" (40 mm) Globe | 1½" (40 mm) Angle | 2" (50 mm) Globe | 2" (50 mm) Angle | ||
75 | 20 | 22 | 4 | 9 | ||
95 | 20 | 21 | 5.5 | 9 | ||
115 | 21 | 21 | 7.5 | 9.5 | ||
135 | 22 | 21 | 9 | 10 | ||
150 | 25 | 23 | 12 | 11 | ||
200 | 27 | 24 | 14 | 12 | ||
325 | 47 | 41 | 26 | 19 | ||
400 | 65 | 59 | 33 | 24 | ||
500 | 96 | 92 | 43 | 32 | ||
625 | 56 | 45 | ||||
775 | 74 | 64 |
Documents
Select Type
- All Documents
- Manuals
- Marketing
- Specifications
- Replacement Parts
PGV-151 | DWG | DXF | ||
PGV-151 With Accu Sync | DWG | |||
PGV-151 with shutoff valve | DWG | DXF | ||
PGV-151 with unions | DWG | DXF | ||
PGV-151 with unions and shutoff valve | DWG | DXF | ||
PGV-201 | DWG | DXF | ||
PGV-201 With Accu Sync | DWG | |||
PGV-201 with shutoff valve | DWG | DXF | ||
PGV-201 with unions | DWG | DXF | ||
PGV-201 with unions and shutoff valve | DWG | DXF |
Support
Training
Get recent hires up-to-speed quickly with this innovative training program that provides crewmembers with the foundational knowledge needed to successfully install, maintain, and troubleshoot irrigation valves in the field. This program provides learners with an overview of valve components and introduces techniques and best practices that help ensure an efficient, long-term installation.