When installing nozzles, you must also correctly set the stator to ensure proper speed of rotation. Failure to correctly set the stator may cause a non-rotation condition.
- Remove the riser assembly from the body by turning counterclockwise on the body cap.
- Remove the filter screen to access the stator by pulling outward.
- The stator has a protruding tab that aligns with a pointer. Remove the stator by grasping this tab with pliers and pulling outward.
- Replace the stator so the pointer is set to the number with the nozzle number installed.
- Visually check for proper assembly of nozzles, set screws, and stator. Reverse the preparation procedure to reassemble the unit.
Nozzle/Stator Chart | |
---|---|
Nozzle Number | Stator Position |
33 | 33 |
38 | 38 |
43 | 43 |
48 | 48 |
53 | 53 |
63 | 63 |