The decoder will not respond after a firmware update
“Comm Unsuccessful”
Problem
- ICD-HP will not communicate with decoder.
- “Comm Unsuccessful”
Cause
- No power to decoder.
- Decoder Programming cup disconnected.
- Batteries low.
- The decoder is damaged.
Solution
- Check controller power to two-wire path, or connect power leads to decoder.
- Check Programming Cup connection to decoder and ICD-HP.
- Check battery display or retry with USB power if available.
Stations will not turn on.
Cause
- No solenoid connected.
- Decoder is powered from ICD-HP power leads.
- No power on two-wire path.
- Master Valve not on (station solenoid is on, but no water).
- Decoder is in IDS/Viking control system.
Solution
- Check solenoid connections.
- Station activation not possible.
- Check two-wire path and controller power.
- Start station with MV from controller or remote.
- Program dummy station numbers into decoder.
Decoder will not respond after firmware update.
Cause
- Stuck in bootloader mode.
Solution
- Repeat firmware update steps and allow to complete.
Poor battery life.
Cause
- Display backlight will reduce battery life.
Solution
- Reduce timer or turn off backlight display.
- Use USB power whenever possible.
- Do not leave ClikTM Output Tester or Flow Output
Tester functions active, or connected to sensor.
Dual/Pilot decoder not recognized by hand held.
Cause
- Old firmware.
Solution
- Update to latest version 1.11.
Communicating Asterisk * Symbol
The * is letting the user know that the ICD-HP is in process of communicating with the decoder. If it is there for a long period of time, the ICD-HP is retrying due to communication failures. The decoder may be damaged.