For best performance, pair a Hunter valve with a Hunter DC-latching solenoid (P/N #458200). However, existing irrigation systems can be retrofitted with another manufacturer's valve and solenoid.
Hunter has tested and published a retrofittable compatibility chart that operates with the Hunter SVC, WVC, NODE, NODE-BT and XC Hybrid battery-powered controllers requiring 9-11 VDC to function. Some listed DC-latching solenoids below require a reduced system pressure, under 150 PSI (10.34 bar/1034.25 kPa), to ensure proper operation.
Use our interactive lookup to find a Hunter Distributor near you. Get Hunter
Solenoid | Valve |
---|---|
Baccara G75-0-10002 | Baccara G75-S-50162 ¾” valve |
Baccara G75-0-10002 | Baccara G75-S-60162 1” valve (max. 75 PSI) (max. 5 bar/517 kPa) |
Bermad S392-2 | Bermad 200 Series valve (max. 50 PSI) (3 bar/344 kPa) |
Nelson 8090 | Nelson 7917 Series valve (max. 50 PSI) (3 bar/344 kPa) |
Rain Bird TBOSPSOL | Rain Bird DV100 and PEB100 valves |
Irritrol E2003 | (Discontinued) Irritrol 100 Series valve (max. 80 PSI) (6 bar/552 kPa) |
Irritrol DCL | 100, 200B, 205, 311A, 700 Series, 2400/2600, 2500 and 2700 Series valve (max. 120 PSI) (max. 8 bar/827kPa) |
Toro DCLS-P | EZ-Flo Plus, TPV, P-220, P-220S, 220 Services valves |
Still need help? We're here.