- Secure one screw into the wall. Install screw anchors if attaching to drywall or masonry wall.
- Slide the keyhole on top of the controller over the screw.
- Secure the controller in place by installing screws in the holes below the terminal strip.
Connecting Valves
- Route valve wires between the control valve location and controller.
- At valves, attach a common wire to the black solenoid wire on all valves. Attach a separate control wire to the remaining red wire of each valve. All wire connections should be done using waterproof connectors.
- Route the valve wires through the conduit. Attach the conduit through the bottom right side of the controller.
- Secure the valve common wire to the C (Common) screw on the terminal strip. Attach each of the individual valve control wires to the appropriate station terminals and tighten their screws.
IMPORTANT: The XCH operates DC latching solenoids only (order Hunter P/N: 458200). 24 VAC solenoids will NOT operate with the XCH. DC solenoids can be easily identified by red and black leads. The red lead is attached to the station output, while the black lead is attached to the common wire.