Hunter prefers using Hunter valves with Hunter DC-latching solenoids (P/N #458200) for best performance. However, existing irrigation systems can be retrofitted with another manufacturer’s valve and solenoid.

Hunter has tested and published a retrofittable compatibility chart with the Hunter Wireless Valve Link battery-powered controller requiring 9-11 Volts DC. (Some listed DC-latching solenoids below require a reduced system pressure, below 150 PSI (10.34 bars/1034.25 kPa), to ensure proper operation)

Find a Hunter Distributor closest to you using our interactive lookup.  Get Hunter

SolenoidValve
Hunter DC Solenoid P/N 458200Compatible with all Hunter Valves
Baccara G75-0-10002Baccara G75-S-50162 ¾” valve
Baccara G75-0-10002Baccara G75-S-60162 1” valve (max. 75psi)(5.17 bars/517.12 kPa)
Bermad S392-2Bermad 200 Series valve (max. 50psi)(3.45 bars/344.75 kPa)
Nelson 8090Nelson 7917 Series valve (max. 50psi)
Rainbird TBOSPSOLRain Bird DV100 and PEB100 valves
Irritrol E2003(Discontinued) Irritrol 100 Series valve (max. 80psi)(5.52 bars/551.6 kPa)
Irritrol DCL                          100, 200B, 205, 311A, 700 Series, 2400/2600, 2500 and 2700 Series valve (max. 120psi)
Toro DCLS-PEZ-Flo Plus, TPV, P-220, P-220S, 220 Services valves