Problem | Causes | Solution |
---|---|---|
WVL Not Watering | Dead batteries. WVL not addressed. Improper solenoid or solenoid disconnected. WVL is out of communication range. | Use the manual test function and replace batteries. Verify WVL address (start from controller) Use manual test function, check solenoid wiring including polarity (red and black) Improve radio communications |
Multiple Stations activate | Possible duplicate addresses in WVLs. | Stop all irrigation, then start one of the stations. If multiple stations start, change the address in one of the WVLs. |
WVOM Beeping | No response from WVL. Low battery warning from WVL. | Use WVL app to read which condition is being reported Replace batteries and/or improve communications, as indicated |
WVOM Beeping | WVL Repeater lost battery charge | Relocate the Repeater to full sun. |
Controller Err Message | No response from WVL. Low battery warning from WVL. Possible failure on another output module. | Use WVL app to read which condition is being reported Replace batteries, improve communications, as indicated Troubleshoot other output modules |
Station turns on for 1 second, then turns off | WVL is wired to AC solenoid (not compatible). | Replace the solenoid with the required DC solenoid (Hunter model 458200). Red wires to red, black wires to black. |
Still need help? We're here.
Tell us what you need support with and we'll find the best solution for you.