WVL - Troubleshooting Chart

ProblemCausesSolution
WVL Not WateringDead batteries.
WVL not addressed.
Improper solenoid or solenoid disconnected.
WVL is out of communication range.
Use the manual test function and replace batteries.
Verify WVL address (start from controller)
Use manual test function, check solenoid wiring including polarity (red and black)
Improve radio communications
Multiple Stations activatePossible duplicate addresses in WVLs.Stop all irrigation, then start one of the stations. If multiple stations start, change the address in one of the WVLs.
WVOM BeepingNo response from WVL.
Low battery warning from WVL.
Use WVL app to read which condition is being reported
Replace batteries and/or improve communications, as indicated
WVOM BeepingWVL Repeater lost battery chargeRelocate the Repeater to full sun.
Controller Err MessageNo response from WVL.
Low battery warning from WVL.
Possible failure on another output module.
Use WVL app to read which condition is being reported
Replace batteries, improve communications, as indicated
Troubleshoot other output modules
 
Station turns on for 1 second, then turns offWVL is wired to AC solenoid (not compatible).Replace the solenoid with the required DC solenoid (Hunter model 458200). Red wires to red, black wires to black.

 

Still need help? We're here.

Tell us what you need support with and we'll find the best solution for you.

Contact Support