PILOT - View Logs

The controller maintains three sets of logs. 

  • Controller Log: This log records events that affect the controller. It is a high-level log that indicates when major changes are made to controller programming or operation. It can also be used with the Alarm and Station Logs to troubleshoot controller issues. This log has a maximum of 250 records.
  • Alarm Log: This log holds records of various alarm conditions encountered by the controller. It can be used to pinpoint when and why events affecting irrigation occurred. This log has a maximum of 250 records.
  • Station Log: This log holds records of all station activity in the controller. It will provide detailed information about why a station ran, how long it ran, and why it was interrupted, stopped, or delayed. This log has a maximum of 7,500 records.

These three log settings function very similarly. Here is an example of the Pilot Controller Log.

  1. Press the VIEW LOGS button.

    Image showing the View Logs button.

  2. Select one of the logs.

    Image showing the log select screen.

  3. The log will show one entry at a time starting with the most recent. Use the UP and DOWN buttons to move to other log entries. The TOP button returns you to the most recent log entry.

    Image showing the selected log's entries.

Controller Log

The following table lists all controller log messages (idioms) available in PILOT. In these messages, At Controller means the action was caused by someone standing at the controller. By Central means the action was caused either automatically or manually through a command issued by Pilot CCS.

MESSAGEMEANING
Easy Retrieve has been used to restore FCP programsA person standing at the controller
A specific FCP was Reset by Central The SYNC command was issued from Pilot CCS
Shutdown Set at ControllerThe RAIN SHUTDOWN button was pressed by someone standing at the controller
Shutdown Cancelled at ControllerThe RESUME irrigation button was pressed by someone standing at the controller
Programmable Shutdown Set at ControllerProgrammable shutdown is rain hold
Pause Mode Set at ControllerThe PAUSE button was pressed by someone standing at the controller
Pause Mode Cancelled at ControllerThe RESUME irrigation button was pressed by someone standing at the controller
Shutdown Set by Central The RAIN SHUTDOWN command was sent from Pilot CCS
Shutdown Cancelled by CentralThe CANCEL RAIN SHUTDOWN command was sent from Pilot CCS
Programmable Shutdown Set by CentralThe RAIN SHUTDOWN command was sent from Pilot CCS
Pause Mode Set by CentralThe PAUSE command was sent from Pilot CCS
Pause Mode Cancelled by CentralThe CANCEL PAUSE command was sent from Pilot CCS
Suspend Mode Set by CentralSuspend cannot be issued manually from Pilot CCS. This can only be a sensor response
Suspend Mode Cancelled by CentralSuspend cannot be canceled manually from Pilot CCS. This can only be a sensor response
Programmable Shutdown Timed OutThe rain delay expired
Pause Timed OutThe pause command’s 30-minute timer expired.
Memory Corrupted – Reset to DefaultsCheck facepack
All Data Reset at ControllerA person standing at the controller used SETTINGS+ to reset the controller
Logs Reset at ControllerA person standing at the controller used SETTINGS+ to reset the controller logs
Program Data Reset at ControllerA person standing at the controller used SETTINGS+ to reset the program data in the controller
Irrigation Stopped by CentralThe CANCEL IRRIGATION command was sent from Pilot CC
Irrigation Stopped by Maintenance RadioCommand sent using Maintenance Radio
Pause Mode Set by Maintenance RadioCommand sent using Maintenance Radio
Pause Mode Cancelled by Maintenance RadioCommand sent using Maintenance Radio
FCP Mode Set at ControllerCan only happen if someone enters the SETTINGS- key combination
System Event Mode Set at ControllerCan only happen if someone enters the SETTINGS- key combination
FCP Mode Set by CentralThe SET COURSE DATE AND TIME command was sent from Pilot CCS
System Event Mode Set by CentralThe SYNC COURSE command was sent from Pilot CCS
Programmable Shutdown Cancelled at ControllerThe resume irrigation button was pressed by someone standing at the controller
All FCPs Reset by CentralPilot CCS does not have a command for this
Block Data was reset by CentralThe COURSE SYNC command was sent by Pilot CCS
P/MV Data Reset by the CentralPilot CCS does not have a command for this
A Manual Station Switch Has Changed PositionThese are the toggle switches on the Pilot FC station output modules. Can only happen at the controller.
FCP and System Event Mode Set at ControllerCan only happen if someone uses the SETTINGS- key combination at the controller
FCP and System Event Mode Set by CentralThe SYNC COURSE command was sent by Pilot CCS
Irrigation Was Stopped at ControllerIrrigation was stopped, paused, put on rain delay, etc. by someone at the controller. STOPPED means it was intentional as opposed to an error.
Programmable Shutdown Cancelled by CentralThe CANCEL RAIN SHUTDOWN command was sent from Pilot CCS
Controller Water End Time ReachedWatering stopped
Hardwire Communications Settings Changed at ControllerChanged by someone standing at the controller
Hardwire Communications Settings Changed by CentralPilot CCS does not have a command for this
Radio Communications Settings Changed at ControllerChanged by someone standing at the controller
Radio Communications Settings Changed by CentralPilot CCS does not have a command for this.
Pump/Master Valve Settings Changed at ControllerCan only happen if someone uses the SETTINGS- key combination at the controller
Pump/Master Valve Settings Changed by CentralPilot CCS does not have a command for this
Program Settings Changed at ControllerFCPs
Program Settings Changed by CentralFCPs
Password Changed at ControllerChanged by someone standing at the controller
Password Changed by CentralPilot CC does not have a command for this
Facepack Entered Boot loading ModeSETTINGS+
Facepack Exited Boot loading ModeSETTINGS+
Module Boot loading Process StartedSETTINGS+
Module Boot loading Process Finished (All But Facepack)SETTINGS+
Easy Retrieve Settings StoredChanged by someone standing at the controller
Day Change Hour was Changed at the ControllerChanged by someone standing at the controller
Day Change Hour was Changed by CentralThe SET GLOBALS command was sent from Pilot CCS
Water End Time was Changed at the ControllerChanged by someone standing at the controller
Water End Time was Changed by CentralThe SET GLOBALS command was sent from Pilot CCS
Controller Module Inventory Has ChangedModule was removed or is no longer communicating with the facepack.
Program Was Stopped at ControllerThe stop button was pressed by someone standing at the controller
Program Was Stopped by CentralA program stop command was sent from Pilot CCS
Program Was Stopped by Maintenance RadioCommand sent by Maintenance Radio
Block Was Stopped by Maintenance RadioCommand sent by Maintenance Radio
Time/Date was Changed at Controller (Pilot Only)The time was changed by someone standing at the controller
Time/Date was Changed by Central (Pilot Only)The SET COURSE DATE AND TIME command was sent from Pilot CCS
Station Size is Zero No 10-station modules installed in Pilot FC
Station Size ChangedSomething has changed with Pilot FC 10-station modules
Limit on the Number of Active Stations was ExceededOnly 20 simultaneous stations allowed in Pilot FC
Power was Restored to ControllerPILOT figures out what should be running when power is restored and turns the stations on.
24VAC Voltage/Frequency NotificationIs the course using generator power?
A Station was Stopped by the CentralThe stop command was sent from Pilot CCS
A Station was Stopped by Maintenance RadioCommand sent by Maintenance Radio
A Station was Stopped at the ControllerThe stop button was pressed at the controller
A Station Status Timeout Occurred 
A Station CAN Message FailedCAN is how modules talk to each other. Check facepack.
The Watchdog Timer ExpiredCheck facepack
An Error Trap was Detected 
The Decoder Boot load Process StartedSETTINGS+
The Decoder Boot load Process FinishedSETTINGS+
The 24VAC Frequency is Out of RangeIs the course using generator power?
The 24VAC Frequency is Back in RangeIs the course using generator power?
System Events Deleted by the CentralThe DELETE SYSTEM EVENTS command was sent from Pilot CCS
System Events Deleted at ControllerSETTINGS+
All Logs Cleared by CentralPilot CCS does not have a command to do this
Database Reset at ControllerSETTINGS+
Database Reset by CentralPilot CCS does not have a command to do this
Power was Lost to Controller 
Alarm Log

Alarms consist of an alarm message followed by a reason. The first table below lists possible alarm messages. The second table lists the reasons which may be associated with the alarms.

ALARMSMEANING
Irrigation Has Been MissedStation did not complete full runtime.
A Power Outage Has Occurred 
Power Has Been Restored 
Decoder Module Reported a Fault Check decoder output module
A Station Has Reported a Fault 
A Station Decoder Has Reported a Fault 
An Error Has Occurred with The RTC ClockReplace facepack.
An Error Has Occurred with the CAN HardwareCheck facepack
A Controller Level Fault Has Been Detected 
A Power Fault Has Been Detected 
REASONSMEANING
A Station Level Overload Has Been DetectedCurrent draw at a single station is too high. Check solenoid.
Hardware is Reporting That it is DamagedReplace decoder
Communications to Device Have Been Lost Check decoder cable
Communications to Device Have Been Restored Check decoder cable
Attempt to Configure Device Has FailedCheck module
Transformer Overload at Station ActivationCurrent demand on transformer exceeded capacity upon activation of last station. Check for non-Hunter solenoids.
Transformer Has OverloadedTotal current demand on controller is too high
Transformer Overload ClearedTotal current demand on controller was too high
A CAN Error OccurredCAN is the communication buss between modules in PILOT. Check facepack.
Low Voltage Detected on 24VAC LineSite may be using a generator.
Low Voltage Alarm ClearedSite may be using a generator.
Station Log
MESSAGEMEANING
Station watering was delayed due to a controller level pausePAUSE button pressed by someone standing at the controller
Station watering was missed due to a controller level suspendRuntime is how many minutes the station did not run.
Station run time expired normallyIrrigation complete. Runtime shown will be total minutes run.
Station stopped due to station level overloadShort on station output. Check solenoid. Runtime is minutes station ran before being shut down.
Station was stopped due to a shutoff or shutdown command Runtime is minutes station ran before being shut down.
Station watering was missed due to a station level overloadShort on station output. Check solenoid. Runtime is how many minutes the station did not run.
Station was interrupted due to a controller level pausePause button was pressed at the controller
Station was interrupted due to a sensor suspendPilot does not yet support sensors
Station was interrupted due to a transformer overload24 VAC transformer was overloaded. Check for multiple solenoids per station or non-hunter solenoids.
Station watering was missed due to a transformer overload24 VAC transformer was overloaded. Check for multiple solenoids per station or non-hunter solenoids.
Station running via manual switch was stopped with manual switch10-station module toggle switches. Someone standing at controller
Station running via manual switch timed out and was stopped10-station module toggle switches. Someone standing at controller
Station was interrupted due to too many stations running (current) 
Station watering was missed due to too many stations running (current) 
Station interrupted due to the manual switch being turned to off10-station module toggle switches
Station was interrupted due to no status response from Output Module 
Station watering was missed due to no status response from Output Module 
Station watering was missed due to a shutoff or shutdown command 
Station was interrupted due to damaged station hardwareCheck 10-station output module
Station watering was missed due to damaged station hardwareCheck 10-station output module
Station was stopped due to a manual step up/down command 
Station was stopped due to the Watering End Time being reached 
Station watering stopped by program stop 
Station watering stopped by block stop 
A delay event completed normally 
Station watering was missed due to shutoff by manual switch10-station module toggle switches
Station was stopped due to a transformer overload 
Station was stopped due to too many stations running 
Station was interrupted due to a station level overload 
Station was interrupted due to too many stations running (quantity) 
Station was missed due to too many stations running (quantity) 
Station was stopped due to too many stations running (quantity) 
Station was stopped due to damaged station hardware 
Station was interrupted due to a CAN message failureCAN is how modules talk to each other. Check facepack.
Station was missed due to a CAN message failureCAN is how modules talk to each other. Check facepack.
Station was interrupted due to a low voltage (24VAC) condition 
Station was missed due to a low voltage (24VAC) condition 
Station was interrupted due to output module missing for station 
Station was missed due to output module missing for station 
Station was stopped due to a low voltage (24VAC) condition 