Decoder Module Diagnostic LED Lights
Each decoder output module is equipped with diagnostic LED lights. Each light is labeled on the output module. Normal operations of this module will have the Line Status solid green while the Communicating light will be blinking green occasionally. During an overload status, it is not uncommon to see the Line Status light off and the Decoder Fault light blinking red. When this occurs, no power comes out of the decoder module. This is a safety mechanism so no power will backfeed into the controller and cause any damage. Start removing two-wire paths to get ohm measurements to find which wire path(s) have been compromised.
0-10K ohms Dead Short
10K-100K ohms Partial Short
100K-350K ohms Will have communication issues
350K-600K ohms Fine but possibly may have communication issues
600K-900K ohms Good wire path
900K-1.2M ohms Very good wire path
1.2M+ ohms Excellent or an open wire path
Activity Type | Color and Meaning |
Decoder fault | Blinking red: Decoder has an over-current or overload |
Module or line activity | Blinking green: Blinking red: |
Communicating | Blinking green: Blinking amber: Solid amber: |
Line Status | Blinking green: Solid green: Off: |
Still need help? We're here.
Tell us what you need support with and we'll find the best solution for you.